<?xml version='1.0' encoding='utf-8'?>
<!DOCTYPE register_page SYSTEM "registers.dtd">
<!-- Copyright (c) 2010-2026 Arm Limited or its affiliates. All rights reserved. -->
<!-- This document is Non-Confidential. This document may only be used and distributed in accordance with the terms of the agreement entered into by Arm and the party that Arm delivered this document to. -->
<!--The data contained in this document is preliminary and subject to change or correction following further review. -->
<?xml-stylesheet href="one_register.xsl" type="text/xsl" ?>







<register_page>
  <registers>
  
    <register is_register="True" is_internal="False" is_stub_entry="False">
      <reg_short_name>CNTCR</reg_short_name>
        
        <reg_long_name>Counter Control Register</reg_long_name>

        <power_domain_text>It is <arm-defined-word>IMPLEMENTATION DEFINED</arm-defined-word> whether CNTCR is implemented in the Core power domain or in the Debug power domain</power_domain_text>


      
      

    
  <reg_address
      external_access="False"
    mem_map_access="True"
      power_domain="None"
  >
    <reg_component>Timer</reg_component>
    <reg_frame>CNTControlBase</reg_frame>
    <reg_offset><hexnumber>0x000</hexnumber></reg_offset>
    <reg_instance>CNTCR</reg_instance>
    <reg_access>
      
        
      <reg_access_state>
          <reg_access_type>RW</reg_access_type>
      </reg_access_state>
    </reg_access>
</reg_address>



          <reg_reset_value></reg_reset_value>

      <reg_mappings>
        




      </reg_mappings>

        <reg_purpose>
          
    
      <purpose_text>
        <para>Enables the counter, controls the <xref linkend="#counter_resolution">counter resolution</xref>, and controls counter behavior during debug.</para>
      </purpose_text>

        </reg_purpose>

      <reg_groups>
          <reg_group>Timer</reg_group>
      </reg_groups>
      <reg_configuration>
        
    
      <configuration_text>
        <para>For more information, see <xref linkend="#CEGHAIAF">'Power and reset domains for the system level implementation of the Generic Timer'</xref>.</para>
      </configuration_text>

      </reg_configuration>
      
      
        
      <reg_attributes>
          
    
      <attributes_text>
        <para>CNTCR is a 32-bit register.</para>
      </attributes_text>

      </reg_attributes>
      <reg_fieldsets>
        






<fields id="fieldset_0" length="32">
  <text_before_fields/>
  <field id="fieldset_0-31_18" has_partial_fieldset="False" is_linked_to_partial_fieldset="False" is_access_restriction_possible="False" is_variable_length="False" is_constant_value="False" is_partial_field="False" is_conditional_field_name="False" rwtype="RES0">
    <field_msb>31</field_msb>
    <field_lsb>18</field_lsb>
    <rel_range>31:18</rel_range>
    <field_description order="before"/>
    <field_description order="before">
      <para>Reserved, <arm-defined-word>RES0</arm-defined-word>.</para>
    </field_description>
  </field>
  <field id="fieldset_0-17_8" has_partial_fieldset="False" is_linked_to_partial_fieldset="False" is_access_restriction_possible="False" is_variable_length="False" is_constant_value="False" is_partial_field="False" is_conditional_field_name="False">
    <field_name>FCREQ</field_name>
    <field_msb>17</field_msb>
    <field_lsb>8</field_lsb>
    <rel_range>17:8</rel_range>
    <field_description order="before"><para>Frequency change request. Indicates the number of the entry in the Frequency modes table to select.</para>
<para>Selecting an unimplemented entry, or an entry that contains 0, has no effect on the counter.</para>
<para>The maximum number of entries in the Frequency modes table is <arm-defined-word>IMPLEMENTATION DEFINED</arm-defined-word> up to a maximum of 1004 entries, see <xref linkend="#BABCDIBI">'The Frequency modes table'</xref>. An implementation is only required to implement an FCREQ field that can hold values from 0 to the highest supported Frequency modes table entry. Any unrequired most-significant bits of FCREQ can be implemented as <arm-defined-word>RES0</arm-defined-word>.</para></field_description>
    <field_resets>
      <field_reset reset_type="Timer">
        <field_reset_expression>0x0</field_reset_expression>
      </field_reset>
    </field_resets>
  </field>
  <field id="fieldset_0-7_3" has_partial_fieldset="False" is_linked_to_partial_fieldset="False" is_access_restriction_possible="False" is_variable_length="False" is_constant_value="False" is_partial_field="False" is_conditional_field_name="False" rwtype="RES0">
    <field_msb>7</field_msb>
    <field_lsb>3</field_lsb>
    <rel_range>7:3</rel_range>
    <field_description order="before"/>
    <field_description order="before">
      <para>Reserved, <arm-defined-word>RES0</arm-defined-word>.</para>
    </field_description>
  </field>
  <field id="fieldset_0-2_2-1" has_partial_fieldset="False" is_linked_to_partial_fieldset="False" is_access_restriction_possible="False" is_variable_length="False" is_constant_value="False" is_partial_field="False" is_conditional_field_name="False" reserved_type="RES0">
    <field_name>SCEN</field_name>
    <field_msb>2</field_msb>
    <field_lsb>2</field_lsb>
    <rel_range>0</rel_range>
    <field_description order="before">
      <para>Scale Enable.</para>
    </field_description>
    <field_description order="after"><para>The SCEN bit can only be changed when the counter is disabled, when CNTCR.EN == 0.</para>
<para>If the value of CNTCR.SCEN changes when CNTCR.EN == 1, then:</para>
<list type="unordered">
<listitem><content>The counter value becomes <arm-defined-word>UNKNOWN</arm-defined-word>.</content>
</listitem><listitem><content>The counter value remains <arm-defined-word>UNKNOWN</arm-defined-word> on future ticks of the clock.</content>
</listitem></list>
<para>When the <register_link state="ext" id="ext-cntcv.xml">CNTCV</register_link> register in the CNTControlBase frame of the memory mapped counter module is written to, the accumulated fraction information is reset to zero.</para></field_description>
    <field_values impdef="False">
      <field_value_instance>
        <field_value>0b0</field_value>
        <field_value_description>
          <para>Scaling is not enabled. The counter value is incremented by <hexnumber>0x1</hexnumber>.0000000 for each counter tick.</para>
        </field_value_description>
      </field_value_instance>
      <field_value_instance>
        <field_value>0b1</field_value>
        <field_value_description>
          <para>Scaling is enabled. The counter is incremented by <register_link state="ext" id="ext-cntscr.xml">CNTSCR</register_link>.ScaleVal for each counter tick.</para>
        </field_value_description>
      </field_value_instance>
    </field_values>
    <field_resets>
      <field_reset reset_type="Timer">
        <field_reset_standard_text>AU</field_reset_standard_text>
      </field_reset>
    </field_resets>
    <fields_condition>When FEAT_CNTSC is implemented</fields_condition>
  </field>
  <field id="fieldset_0-2_2-2" has_partial_fieldset="False" is_linked_to_partial_fieldset="False" is_access_restriction_possible="False" is_variable_length="False" is_constant_value="False" is_partial_field="False" is_conditional_field_name="False" rwtype="RES0">
    <field_msb>2</field_msb>
    <field_lsb>2</field_lsb>
    <rel_range>2</rel_range>
    <field_description order="before"/>
    <field_description order="before">
      <para>Reserved, <arm-defined-word>RES0</arm-defined-word>.</para>
    </field_description>
    <fields_condition>Otherwise</fields_condition>
  </field>
  <field id="fieldset_0-1_1" has_partial_fieldset="False" is_linked_to_partial_fieldset="False" is_access_restriction_possible="False" is_variable_length="False" is_constant_value="False" is_partial_field="False" is_conditional_field_name="False">
    <field_name>HDBG</field_name>
    <field_msb>1</field_msb>
    <field_lsb>1</field_lsb>
    <rel_range>1</rel_range>
    <field_description order="before">
      <para>Halt-on-debug. Controls whether a Halt-on-debug signal halts the system counter:</para>
    </field_description>
    <field_values impdef="False">
      <field_value_instance>
        <field_value>0b0</field_value>
        <field_value_description>
          <para>System counter ignores Halt-on-debug.</para>
        </field_value_description>
      </field_value_instance>
      <field_value_instance>
        <field_value>0b1</field_value>
        <field_value_description>
          <para>Asserted Halt-on-debug signal halts system counter update.</para>
        </field_value_description>
      </field_value_instance>
    </field_values>
    <field_resets>
      <field_reset reset_type="Timer">
        <field_reset_standard_text>AU</field_reset_standard_text>
      </field_reset>
    </field_resets>
  </field>
  <field id="fieldset_0-0_0" has_partial_fieldset="False" is_linked_to_partial_fieldset="False" is_access_restriction_possible="False" is_variable_length="False" is_constant_value="False" is_partial_field="False" is_conditional_field_name="False">
    <field_name>EN</field_name>
    <field_msb>0</field_msb>
    <field_lsb>0</field_lsb>
    <rel_range>0</rel_range>
    <field_description order="before">
      <para>Enables the counter:</para>
    </field_description>
    <field_values impdef="False">
      <field_value_instance>
        <field_value>0b0</field_value>
        <field_value_description>
          <para>System counter disabled.</para>
        </field_value_description>
      </field_value_instance>
      <field_value_instance>
        <field_value>0b1</field_value>
        <field_value_description>
          <para>System counter enabled.</para>
        </field_value_description>
      </field_value_instance>
    </field_values>
    <field_resets>
      <field_reset reset_type="Timer">
        <field_reset_number>'0'</field_reset_number>
      </field_reset>
    </field_resets>
  </field>
  <text_after_fields/>
</fields>




<reg_fieldset length="32">
  <fieldat id="fieldset_0-31_18" msb="31" lsb="18"/>
  <fieldat id="fieldset_0-17_8" msb="17" lsb="8"/>
  <fieldat id="fieldset_0-7_3" msb="7" lsb="3"/>
  <fieldat id="fieldset_0-2_2-1" msb="2" lsb="2"/>
  <fieldat id="fieldset_0-1_1" msb="1" lsb="1"/>
  <fieldat id="fieldset_0-0_0" msb="0" lsb="0"/>
</reg_fieldset>


      </reg_fieldsets>

      <access_mechanisms>
          


  
    
      <access_permission_text>
        <para>In a system that supports the Realm Management Extension, the CNTControlBase frame, which includes this register, is implemented only in the Root physical address space.</para>

      </access_permission_text>
      <access_permission_text>
        <para>In a system that supports Secure and Non-secure physical address spaces, the CNTControlBase frame, which includes this register, is implemented only in the Secure physical address space.</para>
      </access_permission_text>





    

      </access_mechanisms>

      <arch_variants>
      </arch_variants>
  </register>
</registers>
<timestamp>2026-03-26 20:27:25</timestamp>
<commit_id>2026-03_rel</commit_id>